Sistemas de filtragem

Unidade de Controle de Fluido FCU 8111 /-Aviação

Description

The FluidControl Unit FCU 8000 Aviation is a special variant of the FCU 8000 series fur use in aircraft Ground Service.

The portable laser particle measuring instrument outputs contamination classes as per NAS 1638 or SAE AS4059 as required by the manufacturer tasks.

The FCU 8000 is connected to the aircraft via a Minimess DN 2 hose using the HYDAC”Rynglok Sampling Valve 1620″.

 

Special features

  • Conforms to Airbus specification for “Validation of hydraulic fluid portable particle counters” [Reference: X29RE0607915]
  • Conforms to Airbus “Service Information Letter (SIL)” 29-081
  • For partial fulfillment of Airbus task 12-32-29-281-001 o Subtask 12-32-29-281-052: Contamination Analysis by particle count
  • For partial fulfillment of Boeing task 20-40-03-200-802 o Subtask 20-40-03-750-002: Limitation for solid particle contamination
  • Integrated data storage for 3,000 measurements
  • Integrated battery for selfsustaining operation
  • Operating pressure up to 3,000 psi

 

Technical Data

General data

Self-diagnosis Continuous measured value display with error indication in display

Measured variables

  • – Particle counts – NAS 1638 (2-5/5-15/15-25/25-50/50-100/>100 µm)
  • – ISO 4406:1987 (>2/>5/>15 µm)
  • – Flow rate

Data memory 3000

measurements Material of sealings EPDM, suitable for types of Skydrol® and Hyjet®

Ambient temperature range 0 … 55 °C

Storage temperature range -20 … 85°C

Relative humidity Max. 90 %, non-condensing

Protection class III (safety extra-low voltage) IP class IP 40 Weight ~ 14 kg

 

Hydraulic data

Calibration ranges

  • NAS 0 … 12
  • ISO 0/0/0 … 23/21/18

Measurement range

  • Particle counts
  • Maximum NAS 15
  • Maximum ISO 25/23/21

Accuracy ± ½ ISO class in the calibrated range

Operating pressure

  • INLET: 1 … 250 bar
  • OUTLET: maximum 3 bar

Hydraulic connectors

  • INLET: Minimess coupling, type 1620
  • OUTLET: connector DN 7

Measurement flow rate 40 … 60 ml/min

Return flow rate = measurement flow rate Permissible viscosity range 1 … 100 mm²/s

Fluid temperature range 0 … 70 °C

 

Electrical data

Supply voltage 24 V DC, +/- 25 %

Network adapter (included in the scope of delivery)

  • Europe 230 V AC, 50Hz
  • UK 240 V AC, 50Hz
  • USA/CDN 120 V AC, 60Hz
  • Australia 240 V AC, 50Hz
  • Japan 100 V AC, 50Hz

Power consumption 25 W max.

Battery Integrated, operation duration ~ 6 hours

Printer Dot-matrix printer integrated

Serial interface RS232

 

Dúvidas?