Eletrônico

Transmissor de Pressão eletrônico HDA 4300 com Flush Membrane IECEx intrisecamente seguro IECEx Dustproof Enclosure IECEx que não produzam faíscas

Description:

The pressure transmitter HDA 4300 in IECEx Intrinsically Safe version has been especially developed for use in potentially explosive atmospheres and is based on the HDA 4000 series. As with the industrial version HDA 4300, the devices with IECEx Intrinsically Safe approval have the field-proven ceramic measuring cell with thick-film strain gauge.

The pressure connection is achieved with an all-welded stainless steel front membrane filled internally with a pressure transfer fluid. The process pressure is transmitted hydrostatically to the measurement cell via the pressure transfer fluid. This device is used for applications in which a standard pressure connection could become blocked, clogged or frozen by the particular medium used.

Further applications include processes where the medium changes regularly and any residues could cause mixing or contamination of the media. Intended areas of application are, for example, the oil and gas industry, in mines, or in locations with high levels of dust, e.g. in mills.

 

Special features:

  • Pressure connection has a flush membrane
  • Accuracy: ≤ ± 0.5 % FS typ.
  • Certificate: IECEx KEM 08.0014X
  • Robust design
  • Very small temperature error
  • Excellent EMC characteristics
  • Excellent long-term properties

 

Technical data:

Input data

Measuring ranges -1 .. 1;-1 .. 9;1; 2.5; 4; 6; 10; 16; 25 bar

Overload pressures 3; 32; 3; 8; 12; 20; 32; 50; 80 bar

Burst pressure 5; 48; 5; 12;18; 30; 48; 75; 120 bar

Mechanical connection

  • G1/2 A DIN 3852
  • G1/2 with additional front O-ring seal
  • G1/4 with additional front O-ring seal

Pressure transfer fluid Silicon-free oil

Torque value

  • 45 Nm forG1/2, G1/2 A
  • 20 Nm for G1/4

Parts in contact with medium¹)

  • Stainless steel: 1.4435; 1.4301
  • Seal: FPM
  • O-ring: FPM

Output data

Output signal, permitted load resistance

  • 4 .. 20 mA, 2 conductor
  • RLmax = (UB – 12 V) / 20 mA [kΩ]

Accuracy to DIN 16086, max. setting

  • ≤ ± 0.5 % FS typ.
  • ≤ ± 1.0 % FS max.

Accuracy at minimum setting (B.F.S.L.)

  • ≤ ± 0.25 % FS typ.
  • ≤ ± 0.5 % FS max.

Temperature compensation zero point

  • ≤ ± 0.02 % FS / °C typ.
  • ≤ ± 0.03 % FS / °C max.

Temperature compensation over range

  • ≤ ± 0.02 % FS / °C typ.
  • ≤ ± 0.03 % FS / °C max.

Non-linearity at max. setting to DIN 16086 ≤ ± 0.5 % FS max.

Hysteresis ≤ ± 0.4 % FS max.

Repeatability ≤ ± 0.1 % FS

Rise time ≤ 1.5 ms

Long term drift ≤ ± 0.3 % FS typ. / year

Environmental conditions

Compensated temperature range -20 .. +85 °C

Operating temperature range -20 .. +60 °C

Storage temperature range -40 .. +100 °C

Fluid temperature range 2) -40 .. +60 °C / -20 .. +60 °C

CE mark EN 61000-6-1 / 2 / 3 / 4

EN 60079-0 / 11 / 26 / 36

Vibration resistance acc. to DIN EN 60068-2-6 at 10 .. 500 Hz ≤ 20 g

Protection class to IEC 60529

  • IP 65 (for male EN 175301-803 (DIN 43650))
  • IP 67 (for M12x1 male, when an
  • IP 67 female connector is used)

Other data

Residual ripple of supply voltage ≤ 5 %

Life expectancy

  • > 10 million cycles
  • 0 .. 100 % FS

Weight ~ 180 g

 

 

 

 