Eletrônico

Posição do transdutor linear HLT 1000-R2

Description:

The sensor works on the principle of magnetostriction. This measuring principle determines with high accuracy the position, distance and/or speed and is based on elapsed time measurement.

On the basis of this non-contact and wear-free measurement system, HYDAC offers a version in pressureresistant stainless steel housing for complete integration in hydraulic cylinders. The different output signals (analogue/CANopen) facilitate the connection of all HYDAC ELECTRONIC GMBH measurement and control devices as well as connection to standard evaluation systems (e.g. also to PLC controls). The main areas of application are in mobile hydraulics.

Special features:

  • High accuracy, e.g. ≤ ± 0.05 % FS for CANopen
  • Very robust housing
  • High resistance to shock and vibration
  • Excellent EMC characteristics
  • Non-contact and wear-free
  • Persuasive price / performance ratio

Technical data:

Input data

Measuring ranges 50 .. 2500 mm

Measured variable Distance, position, speed

Mechanical connection Cylinder-integrated

Housing Stainl. steel: pressure resistance 450 bar

Output data

Signal output Current:

  • 4 .. 20 mA or
  • 20 .. 4 mA

Voltage:

  • 0 .. 10 V or
  • 10 .. 0 V
  • 0.25 .. 4.75 V or
  • 4.75 .. 0.25 V
  • CANopen

Measuring accuracy  

Analogue

Resolution 12 bit  min. 0.1 mm

Non-linearity ≤ ± 0.05 % FS

Hysteresis ≤ ± 0.1 mm

Repeatability ≤ ± 0.1 mm

Temperature coefficient ≤ ± 0.01 % FS / °C

CANopen

Resolution  0.1 mm

Non-linearity ≤ ± 0.05 % FS

Hysteresis  ≤ ± 0.1 mm

Repeatability  ≤ ± 0.1 mm

Temperature coefficient ≤ ± 0.003 % FS / °C

 

Installation position and travel speed

Environmental conditions

Operating temperature range -40 .. +85 °C

Relative humidity 90 %, non-condensing

Storage temperature range -40 .. +85 °C, dry

Vibration resistance to DIN EN 60068-2-6 at 10 .. 500 Hz ≤ 20 g at 5 kHz ≤ 15 g

Shock resistance to ≤ 50 g DIN EN 60068-2-2 (11 ms)

CE mark EN 61000-6-1 / 2 / 3 / 4

EMC

  • Emitted interference DIN EN 61000-6-3
  • Interference resistance DIN EN 61000-6-2

Housing / Stainless steel, pressure-resistant

Protection class to IEC 60529 1) IP 67

Other data

Electrical connection 1) Flying leads

Separate male panel mount connection M12x1

Supply voltage 12 .. 30 V DC

Current consumption without load max. 100 mA

Weight Depends on length

 

 