Filtros

Filtro de linha MFM portas em L-configuração até 100 l/min, até 280 bar

TECHNICAL SPECIFICATIONS

FILTER HOUSING

Construction

The filter housings are designed in accordance with international regulations. They consist of a filter head and a screw-in filter bowl. Standard equipment:

  • with bypass valve
  • without clogging indicator connection
  • filters are supplied phosphated and primed

 

FILTER ELEMENTS

HYDAC filter elements are validated and their quality is constantly monitored according to the following standards:

  • • ISO 2941,
  • ISO 2942,
  • ISO 2943,
  • ISO 3724, ISO 3968,
  • ISO 11170,
  • ISO 16889

Filter elements are available with the following pressure stability values:

  • Betamicron® (BN4HC): 20 bar

 

FILTER SPECIFICATIONS

Nominal pressure 280 bar

Temperature range -10 °C to +100 °C (-30 °C to -10 °C: pmax= 140 bar)

Material of filter head EN-GJS 400-15

Material of filter bowl Cold extruded steel

Type of clogging indicator VD (differential pressure measurement up to 420 bar operating pressure)

Pressure setting of the clogging indicator 5 bar (others on request)

Bypass cracking pressure 7 bar (others on request)

 

SEALS

  • Perbunan (= NBR)

Installation

  • As inline filter

SPECIAL MODELS AND ACCESSORIES

  • Port for clogging indicator in head

COMPATIBILITY WITH HYDRAULIC FLUIDS ISO 2943

  • Hydraulic oils H to HLPD DIN 51524
  • Lubrication oils DIN 51517, API, ACEA, DIN 51515, ISO 6743
  • Compressor oils DIN 51506
  • Biodegradable operating fluids VDMA 24568 HETG, HEES, HEPG
  • Operating fluids with high water content (>50% water content) on request

MAINTENANCE INSTRUCTIONS

  • Filter housings must be earthed.
  • When using electrical clogging indicators, the electrical power supply to the system must be switched off before removing the clogging indicator connectoR


Dúvidas?