Filtros

Filtro de alças Linha de Retorno RFN com elementos para DIN 24550 até 490 l/min, até 10 bar

TECHNICAL SPECIFICATIONS

FILTER HOUSING

Construction

The filter housings are designed in accordance with international regulations. They consist of a filter head, filter bowl and a bolt-on cover plate.

Standard equipment:

  • bypass valve
  • connection for a clogging indicator

FILTER ELEMENTS

HYDAC filter elements are validated and their quality is constantly monitored according to the following standards:

  • ISO 2941
  • ISO 2942
  • ISO 2943
  • ISO 3724
  • ISO 3968
  • ISO 11170
  • ISO 16889

FILTER SPECIFICATIONS

Nominal pressure 10 bar

Temperature range -10 °C to +100 °C

Material of filter head Aluminium

Material of filter bowl Polyamide

Material of cover plate Polyamide (RFN 40 to 100)

Aluminium (RFN 160 to 630)

Type of clogging indicator

  • VR Connection thread G 1/2
  • VMF Connection thread G 1/8

Pressure setting of the clogging indicator 2.5 bar (others on request)

Bypass cracking pressure 3.5 bar (others on request)

SEALS

  • NBR (=Perbunan)

INSTALLATION

  • Tank-top filter

SPECIAL MODELS AND ACCESSORIES

  • On request

SPARE PARTS

  • See Original Spare Parts List

CERTIFICATES AND APPROVALS

  • On request

COMPATIBILITY WITH HYDRAULIC FLUIDS ISO 2943

  • Hydraulic oils H to HLPD DIN 51524
  • Lubrication oils DIN 51517, API, ACEA, DIN 51515, ISO 6743
  • Compressor oils DIN 51506
  • Biodegradable operating fluids VDMA 24568 HETG, HEES, HEPG
  •  Fire-resistant fluids HFA, HFB, HFC and HFD
  • Operating fluids with high water content (> 50 % water content) on request

IMPORTANT INFORMATION

  • Filter housings must be earthed.
  • When using electrical clogging indicators, the electrical power supply to the system must be switched off before removing the clogging indicator connector.

 

Dúvidas?