Eletrônico

Chave de Temperatura Eletrônico ETS 3200 para a instalação do tanque com Menu Navigation to VDMA

Description:

The ETS 3200 is a compact electronic temperature switch with a 4-digit display. With its integrated temperature probe, the ETS 3200 is particularly suitable for direct tank installation and is available in various lengths. Different output models with one or two switching outputs, optionally with an additional  analogue output signal, offer a variety of application possibilities.

The switching points and the associated switch-back points can be adjusted very quickly and easily using the keypad.nFor optimum adaptation to the particular application, the unit has many additional adjustment parameters (e.g. switching delay times, N/C / N/O function, etc.).

 

Special features:

  • Menu navigation according to VDMA
  • 2 switching outputs, up to 1.2 A load per output
  • Optional analogue output signal selectable (4 .. 20 mA / 0 .. 10 V)
  • 4-digit display
  • Display can be rotated in two axes for optimal alignment
  • Switching / switch-back points and many useful additional functions can be set using keypad
  • Display of measured value and unit of measurement in °C or °F

Technical data:

Input data

Measuring range -25 .. 100 °C (-13 .. 212 °F)

Probe length 100; 250; 350 mm

Pressure resistance 50 bar

Hydraulic connection G1/2 A DIN 3852

Torque value 45 Nm

Parts in contact with medium

  • Mech. connection: Stainless steel
  • Seal: FPM

Output data

Accuracy (display, analogue output) ≤ ± 1.0 °C (≤ ± 2.0 °F)

Temperature drift (environment)

  • ≤ ± 0.015 % FS / °C max. zero point
  • ≤ ± 0.015 % FS / °C max. range

Analogue output (optional)

Signal

  • selectable: 4 .. 20 mA load ≤ 500 Ω
  • 0 .. 10 V load min. 1 kΩ
  • corresp. in each case to -25 .. +100 °C

Switch outputs

Type PNP transistor switching output

Switching current max. 1.2 A per output

Switching cycles > 100 million

Rise time to DIN EN 60751

  • t50: 8 s
  • t90: 15 s

Environmental conditions

Ambient temperature range

  • -25.. +80 °C
  • (-25 .. +60 °C acc. to UL spec.)

Storage temperature range -40 .. +80 °C

Fluid temperature range¹) -40 .. +100°C / -25 °C .. +100 °C

CE mark EN 61000-6-1 / -2 / -3 / -4

Vibration resistance according to  DIN EN 60068-2-6 (0 .. 500 Hz) ≤ 10 g

Shock resistance according to DIN EN 60068-2-29 (11 ms) ≤ 50 g

Protection class to IEC 60529 IP 67

 

 