Eletrônico

Chave de Temperatura Eletrônico ETS 3200 para a instalação do tanque com IO-Link Interface

Description:

The ETS 3200 with IO-Link communication interface is a compact, electronic temperature switch with 4-digit display.

With its integrated temperature probe, the ETS 3200 is particularly suitable for direct tank installation and is available in various lengths.

The instrument has a switching output and additional output that can be configured as switching or analogue (4 .. 20 mA or 0 .. 10 V).

Compared with the standard version, the IO-Link interface enables bidirectional communication between the device and the control. Parameterisation and cyclical transmission of process and service data is therefore possible.

The temperature switch series ETS 3200 with communication interface IO-Link according to specification V1.1 was specially designed to connect sensors in automation systems. Typical fields of application are machine tools, handling and assembly  automation, intralogistics or the packaging industry.

Special features:

  • IO-Link interface
  • 1 PNP transistor switching output
  • Additional signal output, can be configured as PNP transistor
  • switching output or analogue output
  • 4-digit display
  • Display can be rotated in two axes for optimum alignment

Technical data:

Input data

Measuring range -25 .. 100 °C (-13 .. 212 °F)

Probe length 100; 250; 350 mm

Pressure resistance 50 bar

Hydraulic connection G1/2 A DIN 3852

Torque value 45 Nm

Parts in contact with medium

  • Mech. connection: Stainless steel
  • Seal: FPM

Output data

Output signals Output 1: PNP transistor switching output

Output 2: can be configured as PNP transistor

switching output or analogue output

Accuracy (display, analogue output) ≤ ± 1.0 °C (≤ ± 2.0 °F)

Temperature drift (environment)

  • ≤ ± 0.015 % FS / °C max. zero point
  • ≤ ± 0.015 % FS / °C max. range

Analogue output

Signal selectable:

  • 4 .. 20 mA load ≤ 500 Ω
  • 0 .. 10 V ohmic resist. min. 1 kΩ corresp. in each case to -25 .. +100 °C

Switch outputs

Type PNP transistor switching output

Switching current max. 250 mA per output

Switching cycles > 100 million

Rise time to DIN EN 60751

  • t50: 8 s
  • t90: 15 s

Parameterisation Via IO-Link interface, with HYDAC programming device HPG 3000 or push buttons on the ETS 3200

Environmental conditions

Ambient temperature range -25 .. +80 °C

Storage temperature range -40 .. +80 °C

Fluid temperature range1) -40 .. +100°C / -25°C .. 100 °C

CE mark EN 61000-6-1 / -2 / -3 / -4

Vibration resistance according to DIN EN 60068-2-6 (0 .. 500 Hz) ≤ 10 g

Shock resistance according to DIN EN 60068-2-29 (11 ms) ≤ 50 g

Protection class to IEC 60529 IP 67

Other data

Supply voltage

  • 9 .. 35 V DC (without analogue output)
  • 18 .. 35 V DC (with analogue output)

Current consumption ≤ 0.535 A with active switching outputs

  • ≤ 35 mA with inactive switching outputs
  • ≤ 55 mA with inactive switching output and analogue output

Residual ripple of supply voltage ≤ 5 %

Display 4-digit, LED, 7-segment, red, height of digits 7 mm

Weight (complete unit including probe)

  • ~ 150 g (probe length 100 mm)
  • ~ 185 g (probe length 250 mm)
  • ~ 210 g (probe length 350 mm)

 

 

Dúvidas?