Trocadores de calor

Sistemas de resfriamento FLKS -3S/1.0/W… FLKS – 3L/1.0/W…

APPLICATIONS

Cooling circuits:

  • Cooling of AC main drives
  • Cooling of motor spindles on machining centres
  • Cooling of transmission and braking systems
  • Cooling of servo and linear motors

CONSTRUCTION

The HYDAC FLKS fluid air cooling system consists of an axial fan, a tank, a submersible pump and a heat exchanger.
The submersible pump built into the plastic tank pumps the coolant through the heat exchanger.
The axial fan provides the necessary cooling air through the heat exchanger.

 

TECHNICAL SPECIFICATIONS

Preferred fluid:

  • Mains water with 30-40% GLYSANTIN G48 PROTECT PLUS (BASF)

Other permissible cooling fluids:

Mains water with 30-40%

  • PARAFLU 11

Mains water with 5-10%

  • MOTOREX COOLANT-F
  • Other coolants on request!

Fluid temperature

  • max. 60 °C

Ambient temperature

  • 0 °C to +40 °C

 Mounting Position:

  • Vertical (tank at the bottom)

Noise level mesured to din45635 part 1

FLKS-3S:

  • 74 dB(A) 4pole 50Hz
  • 79 dB(A) 4pole 60Hz

FLKS-3L:

  • 64 dB(A) 4pole 50Hz
  • 68 dB(A) 4pole 60Hz

DIRECTION OF ROTATION

Pump:

  • when looking at motor fan, clockwise

Cooling fan:

  • when looking at motor fan, clockwise

TANK SIZE:

  • Max. 21 l, Min. 11 l

WEIGHT

  • 43.5 kg

ELECTRICAL CONNECTION

  • Terminal box of electric motor

HYDRAULIC CONNECTION

Pump: P = G 3/4

Heat exchanger: K = G 1

Tank drain: T = G 3/4

Do not reduce pipe cross-section pre-determined by the threaded connections.

ELECTRICAL SPECIFICATIONS

Design voltage range:

380-420 V star / 220-240 V delta – 50Hz

440-480 V star / 254-277 V delta – 60Hz (motor rating x 1.15)

Voltage tolerances to EN 60034-1 ±5%

 